IIEIndustrial Intelligence Engineer

Know where your plant is heading, before the alarm.

IIE tracks how plant variables evolve, flags abnormal trends before any alarm fires and cross-checks the evidence, with the decision always left to your team.

Currently in technical validation, running in a simulated plant environment. The demo replays a real IIE run, and its assistant answers data questions from that run.

IIE dashboard showing a simulated plant P&ID, equipment cards and active alarmsPanel de IIE con el P&ID de una planta simulada, tarjetas de equipos y alarmas activas

IIE running in a simulated plant environment.

Earlier warnings

Spot developing conditions before they reach alarm limits.

Time to threshold

Estimates when a variable would cross its limit if nothing changes.

Cross-checked evidence

Recommendations validated across independent sources.

Operator in control

Risk and confidence levels with an approval gate. Never autonomous.

Clear about what IIE is, and what it is not.

What IIE is

An intelligence layer above your existing systems, connected to plant data and engineering knowledge, built for evidence-based decisions.

What IIE is not

Not a replacement for DCS, SCADA, PLC or SIS. Not an autonomous control system. Not a generic chatbot.

What IIE does

  • Early trend detectionWorking in the demo

    Follows how each monitored variable is evolving and flags abnormal trends before any alarm threshold is reached.

  • Time to thresholdWorking in the demo

    Estimates when a variable would cross its limit if the trend continues, so teams can plan the intervention instead of reacting to it.

  • Failure diagnosisWorking in the demo

    When several variables match a known pattern, such as cavitation in a pump, IIE names it with risk level, confidence and a recommended action, while the pattern is still forming.

  • Forecasting and remaining useful lifeWorking in the software

    Estimates the time until a variable crosses its limit with a Kalman filter and its uncertainty, and fits Weibull models to the time between failures, with MTBF, MTTR and availability. Tested on a virtual plant based on a real plant (tags and data changed for confidentiality), not yet connected to live plant data.

  • Preventive maintenance suggestionsWorking in the demo

    Turns early indicators into preventive actions, such as scheduling a cleaning when differential pressure rises in a heat exchanger without a matching change in flow.

  • Cross-checked evidenceWorking in the demo

    Recommendations pass through redundant 2oo3 and 4oo5 voting across independent evidence sources. A consensus engine adjusts confidence from the operator’s acceptance history, and cross-document checks catch contradictions, such as datasheet versus P&ID.

  • Digital twin of the plantWorking in the demo

    Each asset is a structured object with variables, instrumentation, thresholds, status and history. The data source is interchangeable, so the same engine can move from simulated data to a historian or SCADA.

  • Knowledge from your documentsWorking in the software

    Reads manuals, standards, datasheets and P&IDs (PDF with OCR, Word, Excel, DXF/DWG), classifies them and makes them available to the assistant only after a person approves them. Answers cite the document and page. Not yet connected to a real plant’s manuals.

  • Decision support, human in controlWorking in the demo

    Recommendations in plain language, announced proactively, with risk and confidence levels and an approval gate. IIE never issues autonomous instructions to the plant.

  • Consequence analysisWorking in the software

    Shows what happens in the rest of the plant if one asset runs below its capacity, using the dependencies declared between equipment, and compares scenarios side by side. Calculation only: it never acts on the plant.

  • Alarm management (ISA-18.2 / EEMUA 191)Working in the demo

    Six alarm types with priority by consequence and response time, parent and consequential alarms, and first-out. Detects alarm floods as they happen, says what seems to be causing them and who started them, and supports controlled shelving with a reason, a name and a time limit. The control system keeps annunciating every alarm.

  • Energy and carbon savingsWorking in the demo

    Proposes operating actions that save energy and CO2, each with its calculation basis, a ceiling and a realistic range, always after safety, integrity and production. Savings on an asset with an open condition wait until it is resolved. Tariffs and emission factors are example values until the plant provides its own.

  • Mass and energy balancesWorking in the demo

    With the instruments the plant already has, IIE closes a mass or energy balance around each asset and each declared line section, and reports what does not add up with its margin of error at 95 % and the smallest loss it can detect. It ranks where to look first and tells a real loss from a suspect meter. It does not say where the product went or which compound it is: that requires measuring vents, flare and effluents.

  • Control loopsWorking in the demo

    Simulates the seven control types, from open loop to cascade and feedforward, proposes tuning with SIMC, Lambda, Ziegler-Nichols and Cohen-Coon, and discards fragile settings with the reason. Diagnoses a real loop from its history. Simulation only: it does not touch the plant or safety loops.

  • Operational review in normal operationWorking in the software

    When nothing is in alarm, the assistant still reviews the whole operation: variables close to a limit, trends, data quality, balances that do not close and savings. Each proposal is checked against the plant’s approved documents and cites them, or says it has no documentary support.

  • Signed evidence recordWorking in the software

    Every diagnosis and recommendation is linked to the evidence behind it in an append-only record with a signed hash chain and external anchors, verified at start-up. A person approves or rejects, and that decision is recorded too.

  • Data centers: water and energyWorking in the software

    A second application on the same engine, for cooling plants: chillers, cooling towers, pumps and CDUs. It tracks PUE and WUE, closes the water balance of each tower and the energy balance of each chiller, flags losses nobody measures and estimates the water that could be saved by raising the cycles of concentration. Working on a simulated data center; not yet validated on a real facility.

  • Data centers: optimising water and energyWorking in the software

    For the next 24 hours it proposes the cooling mode (wet, dry or hybrid), the chilled-water temperature, the tower-fan speed and the cycles of concentration, and only when net water (direct plus the water behind the electricity) does not get worse. It checks the saving against a baseline corrected for weather and load, estimates a full year with a 95 % band, gives a signal for the job scheduler, plans thermal-storage dispatch and compares what-if hardware scenarios. IIE proposes; your people decide. Results come from a model with example parameters and a synthetic climate, not yet validated on a real facility.

  • Industrial screenings: heat, pressure and compressed airWorking in the software

    Quick screenings of three common savings: heat integration between process streams (pinch analysis), recovery of pressure that is lost across valves, and compressed-air leaks from the load/unload cycle. They give an order of magnitude to decide where to look first; they are not a detailed design.

  • A chat that answers with live data and checks itselfWorking in the software

    Ask about the state of a plant or a piece of equipment, causes, limits, alarms or applicable standards. The answer is written from the live data, IIE’s own calculations and your loaded documents, and every figure in it is checked against that data before it is shown. It runs with a model on your own computer, so no plant data has to leave the site.

  • Connection to a real plant, read-onlyWorking in the software

    Reads from OPC UA and MQTT with data-quality flags, automatic reconnection and a local memory, so a restart does not start from zero. It only reads: it never writes to the control system. Tested against an OPC UA test server; a real plant still needs commissioning with your data.

  • Users, roles and audit trailWorking in the software

    Access by user and role, and a log of who did what and when, next to the signed evidence record.

  • Produced-water plant (oil and gas)Working in the software

    A third application on the same engine: a virtual produced-water treatment plant with CPI interceptors, flotation cells, nutshell filters, ultrafiltration, reverse osmosis, delivery pumps and a backup tank protected against overflow. It has its own control philosophy (loops, interlocks, permissives and sequences) and a live process drawing in which valves and pumps show their state and the tanks fill according to their level. Working on a simulated plant with example parameters; not yet validated on a real facility.

  • Audited balances and a bank of simulated decisionsWorking in the software

    Every simulated run is audited: the mass balance closes within 0.0002 % of the water entering, no water is lost without being declared, and no pump exceeds a physically possible efficiency. A bank of 81 simulated runs over six scenarios quantifies the effect of operating decisions (recirculation, antiscalant dose, sludge interval, backwash threshold) and shows each energy saving next to its hidden cost in oil carry-over and membrane fouling. Figures come from example parameters, not from a real plant.

  • Control-loop tuning with dynamic simulationWorking in the software

    Pick a loop (for example the level of each CPI interceptor), change its gain, integral time or setpoint and watch how it would respond to a crude surge, with the current values and with the tuning IIE proposes: controlled variable, controller output and oil carry-over. It is a laboratory: it sends no commands to the plant.

What IIE is built on

Engineering knowledge

Control, instrumentation and process practice, encoded so the software reasons in plant-engineering terms.

International standards

International standards such as ISO 20816-3 for vibration and ISA-18.2 for alarm management, with every recommendation citing its basis.

Applied AI and software

Production-grade software and language models that show their evidence instead of asking to be trusted.

© 2026 IIE Technologies Group, Inc.All rights reserved.